Compare data center regulation

Italy, France, Switzerland, Austria and Slovenia, measure by measure. EU-wide rules are listed once. National and regional or local rules are shown side by side, each with its status, effective date and source.

MeasuresItalyFranceSwitzerlandAustriaSlovenia
EU-wide / supranational88088
National28110
Regional / local21060
Total12171158
Coverage last reviewed2026-09-242026-09-24not yet re-reviewed2026-09-24not yet re-reviewed

Up to 7 countries at a time. A zero means no measure was found in this compilation, not that none exists.

What was checked, per country
  • Italy (2026-09-24): National single-authorisation procedure (DL 21/2026 art. 8) checked on Normattiva; enabling bill C.1928/S.1821 on Camera/Senato. Lombardy law (May 2026) and 2024 guidelines from the regional news agency, law number and BURL publication not verified. No EED transposition decree or ARERA data-centre rule confirmed.
  • France (2026-09-24): National energy-efficiency/EED transposition (Code de l'énergie L.236, décret 2025-1382), tax (accise eco-conditions), planning (PINM) and grid (RTE) rules checked on Légifrance and official sites; Arcep reporting included. Local: only Marseille checked (2023 municipal strategy, via regional press; official deliberation not fetched). Aix-Marseille-Provence PLUi, SDRIF-E (Île-de-France) and Plaine Commune not confirmed.
  • Austria (2026-09-24): Federal and state law searched via the RIS open-data API for 'Rechenzentren': federal EEffG §72a disclosure, Lower Austria zoning, and waste-heat duties in Vienna, Upper Austria, Burgenland, Tyrol and Vorarlberg added. Other states (Styria, Carinthia, Salzburg) not confirmed.

EU-wide / supranational (shared)

These apply to the selected EU countries (Italy, France, Austria and Slovenia), not to Switzerland.

MeasureType · categoryStatusEffectiveApplies toSource
Commission Delegated Regulation (EU) 2024/1364: common EU data-centre rating scheme (phase 1)
Mandates reporting of installed IT power, energy, PUE, ERF/waste-heat, WUE and renewable share via the European DC database; first round 15 Sep 2024, then annual.
Fixes the exact KPIs and data a ≥500 kW site must submit to the European database each year (first round 15 Sep 2024). It sets no performance threshold.
regulation · energy efficiencyIn force2024All selected EU countriessource
Energy Efficiency Directive (EU) 2023/1791: data centre monitoring & reporting (Art. 12)
DCs >=500 kW must annually report energy, power/water use, PUE, waste-heat reuse and renewable share. In force 10 Oct 2023; transposition by 11 Oct 2025.
Sites with ≥500 kW of installed IT power must report energy use, PUE, water, waste-heat reuse and renewable share every year to the European data-centre database. A reporting duty, with no EU-level PUE ceiling.
directive · energy efficiencyIn force2023All selected EU countriessource
Ecodesign Regulation (EU) 2019/424: servers & data storage
Minimum PSU efficiency/power factor, idle-power limits, active-state efficiency, plus material-efficiency and info requirements (secure erase, firmware updates, dismantling).
Applies to the servers and storage products installed, not to the building: equipment sold in the EU must meet PSU-efficiency, idle-power and material-efficiency requirements.
ecodesign · energy efficiencyIn force2019All selected EU countriessource
Climate Neutral Data Centre Pact (CNDCP)
Targets: PUE 1.3 (cool)/1.4 (warm) by 2025/2030; 75% renewable/CFE by 2025 & 100% by 2030; WUE and heat-reuse assessment; server circularity.
Voluntary: binds only operators that sign it to PUE (1.3/1.4), renewable-power, water and heat-reuse targets. No legal obligation on non-signatories.
self-regulatory · energy efficiencyVoluntary commitment2021All selected EU countriessource
F-Gas Regulation (EU) 2024/573
HFC quota phase-down, bans/use-restrictions on high-GWP F-gases in refrigeration/AC, leak checks, recovery and reporting, pushing DCs to low-GWP/natural refrigerants.
Phases down high-GWP refrigerants used in cooling. Drives chiller/refrigerant choices and retrofit of existing plant.
regulation · refrigerantsIn force2024All selected EU countriessource
Renewable Energy Directive III (RED III) 2023/2413
Higher renewable shares, faster permitting, heating & cooling sector targets and district-heating integration that can value DC waste heat.
Sets binding national renewable targets for member states, not duties on an individual site; indirectly eases PPAs, permitting and district-heating outlets for waste heat.
directive · renewableIn force2023All selected EU countriessource
EU Taxonomy Regulation (EU) 2020/852
CSRD companies report Taxonomy-aligned turnover/capex/opex; DC alignment hinges on energy-efficiency criteria (EU Code of Conduct/CEN-CENELEC).
No direct duty on the site: operators that report under CSRD disclose how much of their activity is taxonomy-aligned, which for data centres hinges on following the EU Code of Conduct on data-centre energy efficiency. Matters mainly for green financing.
regulation · sustainability reportingIn force2020All selected EU countriessource
Corporate Sustainability Reporting Directive (CSRD) 2022/2464
Mandatory assured disclosure of climate, energy, water, emissions, resource-use and governance; scope narrowed by 2025 Omnibus/'Stop-the-clock'.
Requires the operator to disclose energy / water / carbon data. A compliance and transparency burden rather than an operating limit.
reporting · sustainability reportingPhased2024All selected EU countriessource

National

Italy2
DL 21/2026 art. 8 – single authorisation procedure for data centres (converted by L. 49/2026)
regulationzoning
In force · effective 2026

Maximum 10 months from the completeness check, extendable once by at most 3 months in exceptional cases; EIA deadlines halved; one application covers AIA, EIA, landscape, water, emissions and planning consents. In force 21 Feb 2026; converted with amendments by L. 10 April 2026 n. 49 (text in force from 19 Apr 2026).

A data centre and its grid connection get one combined permit from the integrated-environmental-permit (AIA) authority within at most 10 months, with environmental-impact deadlines halved.

Governo / MASE; regional/provincial AIA authorities · source
Data-centre enabling bill (DDL delega sui centri di elaborazione dati, C.1928 → S.1821)
regulationdigital policy
Proposed · effective 2026

Legislative decrees within 6 months of entry into force; principles include simplified EIA/AIA, derogations from urban-planning rules, energy self-generation, waste-heat recovery via district heating and contributions to host municipalities. Senate: in committee (last update 23 Jun 2026).

If enacted, the Government would have 6 months to adopt decrees giving data centres simplified EIA/AIA procedures, derogations from local planning rules and support for on-site generation and waste-heat reuse in district heating.

Parlamento (Camera dei deputati / Senato) · source
France8
Reduced excise (accise) on electricity for data centres
tax relieftax
In force · effective 2019

Reduced accise rate on the electricity a data centre consumes above 1 GWh/yr, conditional on an ISO 50001 energy-management system (with further relief for electro-intensive sites).

Typical effect of this kind of measure: Lowers the cost of building or running a data center here (tax breaks, cheaper power, grants). A siting incentive: pulls investment in rather than constraining it.

DGFiP (accise on electricity transferred from DGDDI/douane in 2022) · source
Code de l'énergie art. L.236-1 to L.236-3 – data-centre energy performance (loi n° 2025-391, art. 25)
regulationheat reusein friction index
In force · effective 2025

L.236-1: installed server-room power ≥500 kW → transmit administrative, environmental and energy data to the EU platform and make it public. L.236-2: ≥1 MW → valorise waste heat (derogations by decree). L.236-3: formal notice of at most 1 year, then an administrative fine of at most €50,000 per data centre. Created by loi n° 2025-391 of 30 Apr 2025; most provisions in force 1 Oct 2025.

A site with ≥500 kW of server-room power must publish its energy and environmental data; from 1 MW it must reuse its waste heat, with fines of up to €50,000 per data centre for non-compliance.

Parlement / Ministère chargé de l'énergie (DGEC) · source
Décret n° 2025-1382 du 29 décembre 2025 – data-centre declaration, annual reporting and ERF ≥ 0.20 heat-reuse threshold
reportingheat reuse
In force · effective 2026

Declaration within 2 months of commissioning; administrative, environmental and energy information for the previous year by 15 May each year; deemed to valorise waste heat if ERF (Annex III of Delegated Reg. 2024/1364) ≥ 0.20, with a cost-benefit/derogation route for sites where it is not attainable. In force 1 Jan 2026.

A new site must be declared within 2 months of commissioning and report every year by 15 May; it only counts as reusing waste heat if its ERF is at least 0.20.

Gouvernement (Premier ministre; ministre chargé de l'énergie) · source
Loi REEN n° 2021-1485, art. 28 – heat-reuse and water eco-conditions on the reduced electricity excise for data centres
tax relieftax
Adopted, implementing act pending · effective 2022

Amends art. 167 of loi de finances 2021: criteria go from seven to nine (valorise waste heat, e.g. via a heating/cooling network, or meet a numeric efficiency indicator set by decree; and meet a cooling-water indicator set by decree). A Senate report of Feb 2026 still called for the implementing decree.

To keep the reduced electricity excise rate, a data centre will have to reuse its waste heat or meet a decree-set efficiency indicator, and meet a cooling-water indicator.

Parlement; Ministère de l'Économie · source
Loi n° 2026-403 (simplification de la vie économique), art. 35 – data centres eligible for 'projet d'intérêt national majeur'
designationzoning
In force · effective 2026

Qualification by decree where the project's purpose and scale (investment, installed power) matter for the digital or ecological transition or national sovereignty; effect limited to a State-led planning-compatibility procedure. ZAN exemption censured (Décision 2026-903 DC, 21 May 2026). Law of 26 May 2026.

A large data centre can be designated a project of major national interest by decree, letting the State align local planning documents with it; it does not by itself grant an environmental derogation.

Parlement; État (décret de qualification) · source
Arcep annual environmental data collection from data-centre operators (Décision n° 2024-2545)
reportingsustainability reporting
In force · effective 2024

Revenue ≥ €10M or installed IT power ≥ 100 kW (reduced set for 100–500 kW operators under €10M); energy by use, water withdrawals, artificialised land, refrigerant emissions and GHG for the previous year, due 31 March. Replaces Décision 2023-2488; published in the JO on 14 Mar 2025.

Operators with French revenue ≥ €10M or IT power ≥ 100 kW must report energy, water, land take, refrigerants and GHG data to Arcep by 31 March each year.

Arcep (homologated by ministerial arrêté) · source
State identification of 63 data-centre sites and national siting guide (DGE, 2025)
designationzoning
In force · effective 2025

63 identified sites; 'Guide pour l'implantation de centres de données' (Nov 2025); support via DREETS, regional development agencies and prefectures.

Developers can target 63 pre-identified sites and get support from prefectures, DREETS and regional development agencies; ADEME can co-fund heat recovery.

Direction générale des Entreprises (Ministère de l'Économie) · source
RTE fast-track connection sites and shared connection zones for data centres
designationgrid
In force · effective 2025

5 fast-track sites (4 allocated to operators meeting technical and financial requirements); shared zones of about 1,200 MW (south Île-de-France) and 500 MW (Marseille area); procedure approved by CRE.

Fast-track sites next to the 400 kV grid and shared connection zones (~1,200 MW south of Île-de-France, ~500 MW near Marseille) shorten connection times and pool network costs.

RTE (procedure approved by CRE) · source
Switzerland1
CO2 levy exemption via reduction-commitment / target agreements
incentiveenergy
In force · effective 2013

Refund/exemption of the CO2 levy in exchange for a legally-binding emissions-reduction/energy-efficiency target (administered via act/EnAW).

Can cut operating cost: a site that signs a binding emissions-reduction / efficiency target can have the CO₂ levy on its fossil fuels (e.g. backup or heating fuel) refunded. It is an opt-in exemption, not an efficiency ceiling such as a PUE limit.

Bundesamt fur Umwelt (BAFU/FOEN) · source
Austria1
Bundes-Energieeffizienzgesetz §72a – public KPI disclosure by data centres ≥500 kW
reportingsustainability reporting
In force · effective 2024

≥500 kW installed IT power; first by 15 May 2024, then yearly by 15 May; defence and civil-protection data centres exempt; trade secrets excluded.

Owners and operators of data centres with ≥500 kW installed IT power must publish, on their own website and every year by 15 May, their area, power, data traffic and KPIs on energy, temperature setpoints, waste-heat use, water use and renewables.

Nationalrat / BMK (BGBl. I Nr. 29/2024) · source
Slovenia0

No national measures compiled.

Regional / local

Italy2
Lombardy regional law on the opening of new data centres (approved May 2026)
Regional: Lombardiaplanningzoning
Adopted (publication not verified) · effective 2026

Siting priority for disused/brownfield areas; high-efficiency cooling and reduced drinking-water use; waste-heat recovery via district heating; environmental and territorial compensation for municipalities; uniform procedures with fixed timelines. Law number, thresholds and BURL publication not verified.

Projects in Lombardy are steered to brownfield or disused land, expected to use efficient, low-drinking-water cooling and district-heat reuse, and must fund environmental and territorial compensation for host municipalities.

Regione Lombardia (Consiglio regionale) · source
Lombardy data-centre siting guidelines for local authorities (Giunta, June 2024)
Regional: Lombardiaplanningzoning
In force · effective 2024

Non-binding guidelines: priority to disused, brownfield or regeneration areas; energy autonomy; landscape and environmental protection. DGR number not found.

Municipalities assessing a data-centre application follow regional guidance favouring disused, brownfield or regeneration sites and energy self-sufficiency; non-binding, but it shapes early site selection.

Regione Lombardia (Giunta) · source
France1
Marseille municipal strategy for planned and regulated siting of subsea cables and data centres (Oct 2023)
Local: Marseilleplanningzoningin friction index
In force · effective 2023

Deliberation of 20 Oct 2023 'Stratégie municipale pour une implantation planifiée et régulée des câbles sous-marins et des data centers'; criteria: already artificialised, polluted or disused land; land and marine biodiversity; link with renewable production and heat recovery; local employment; architectural quality. A consultative commission reviews projects; the city states it has no decision power over subsea cables.

Projects in Marseille are assessed by a municipal consultative commission against siting criteria (brownfield or already-artificialised land, biodiversity, renewables and heat recovery, local jobs, urban integration); the criteria are not binding, as planning powers sit with the Métropole.

Ville de Marseille (conseil municipal) · source
Switzerland0

No regional / local measures compiled.

Austria6
NÖ Raumordnungsgesetz 2014 §§11c, 18c – dedicated 'Bauland-Sondergebiet-Rechenzentrum' zoning and state site ordinances
Regional: Lower Austria (Niederösterreich)planningzoningin friction index
In force · effective 2026

>0.5 ha only in the special zone; >3 ha only where a §11c state ordinance exists (it lapses if not zoned within 5 years, extendable by up to 3); 500 m aggregation; power supply and waste-heat use must be considered. In force 9 Jun 2026 (LGBl. 38/2026).

In Lower Austria, a data centre over 0.5 ha can only be built on land zoned 'Sondergebiet-Rechenzentrum'. Zoning over 3 ha needs a prior state site ordinance, which must secure power supply and consider waste-heat use. Facilities within 500 m of each other count together.

Land Niederösterreich (Landesregierung) · source
WERUG 2020 §10 – waste-heat use obligation for data centres >1 MW
Regional: Viennaregulationheat reusein friction index
In force · effective 2026

Nominal total energy input >1 MW; exemption only via a §7 CBA showing technical or economic infeasibility. Current version in force 17 Jul 2026 (LGBl. 28/2026).

Existing Vienna data centres over 1 MW must use their waste heat or other heat recovery, unless a cost-benefit analysis shows it is not feasible. Operators can apply for a formal finding that no obligation applies.

Land Wien · source
Oö. Energieeffizienzgesetz §§11-12 – data-centre waste-heat use and cost-benefit analysis
Regional: Upper Austria (Oberösterreich)regulationheat reusein friction index
In force · effective 2026

>1 MW nominal total energy input; CBA when new or substantially modernised. In force 1 Apr 2026 (LGBl. 29/2026).

Data centres over 1 MW in Upper Austria must use their waste heat unless a cost-benefit analysis shows it is infeasible. The CBA is mandatory for new or substantially modernised data centres.

Land Oberösterreich · source
Burgenländisches Energieeffizienzgesetz §§11-12 – data-centre waste-heat use and cost-benefit analysis
Regional: Burgenlandregulationheat reusein friction index
In force · effective 2025

>1 MW nominal total energy input. In force 30 Dec 2025 (LGBl. 105/2025).

Data centres over 1 MW in Burgenland must use their waste heat unless a cost-benefit analysis proves it infeasible. The CBA is required when new or substantially modernised.

Land Burgenland · source
Tiroler Energieeffizienzgesetz §17 – Waste-heat cost-benefit analysis for data centres >1 MW
Regional: Tyrol (Tirol)regulationheat reusein friction index
In force · effective 2026

Nominal total energy input >1 MW; new builds and substantial modernisation. In force 31 Mar 2026.

A new or substantially modernised Tyrolean data centre over 1 MW must assess waste-heat use and district-heating/cooling connection in a cost-benefit analysis that also covers heat-capturing cooling designs.

Land Tirol · source
Betreiberpflichtengesetz §12 – Waste-heat assessment for data centres >1 MW
Regional: Vorarlbergregulationheat reusein friction index
In force · effective 2026

Nominal total energy input >1 MW; new builds or substantial modernisation. Version in force from 18 Sep 2026.

Building or substantially modernising a Vorarlberg data centre over 1 MW requires an assessment of waste-heat use and district-heating/cooling connection, including heat-capturing cooling solutions.

Land Vorarlberg · source
Slovenia0

No regional / local measures compiled.

Research compilation, not legal advice. Re-check each measure's status with the cited authority. Some scope and status labels have been corrected from the source compilation (for example, municipal rules that were tagged national, and voluntary pacts that were shown as in force).